A.O. SMITH

ENERGY SAVING PRODUCT

FEATURES:

CODE COMPLIANCE: H.U.D., ASHRAE/IES 90.1b-1992 and 1990 NAECA.

  • A.G.A. CERTIFIED - To ANSI standards for residential water heaters. All models are approved for use in combined appliance applications.
  • FOAM INSULATION - Minimizes radiant heat loss.
  • GLASS-LINED TANK - Glass, specifically developed by A.O. Smith ceramic research for water heater use, is fused to steel at 1600F., providing corrosion protection for years of dependable use. Proven reliable in millions of water heaters for over 50 years.
  • DIP TUBE - Carries inlet water deep into tank.
  • ANODE - Tank-mounted, screw-in anode for longer tank life.
  • THERMOSTAT - Designed for long service life. Safety shutoff provided. Propane models have built-in filter and dirt leg provided.
  • BURNER - All steel, multiport burner for improved combustion efficiency. FSG-75 & FSG-100 have a cast iron burner.
  • SELF CLOSING INNER DOOR - Supplied as a standard feature on all models.
  • DRAFT DIVERTER - Supplied with screw anchor tabs for secure connection to the top cover.
  • NON-LINTING ENERGY SAVING PILOT
  • DRAIN VALVE - Non-metallic valves.
  • HIGH RECOVERY MODELS AVAILABLE - FSGH/FSGT models are the best value.
  • CALIFORNIA - Models for sale in California are built to special requirements. See California specification sheet available from sales office.

ENERGY SAVER

GAS RESIDENTIAL WATER HEATERS FSG

If the tank should leak any time during the first 6 years, under the terms of the warranty, A.O. Smith will furnish a replacement heater. Installation, labor, handling and local delivery are extra. When used commercially, warranty is for 1 year. THIS OUTLINE IS NOT A WARRANTY. For complete information, consult the written warranty or A.O. Smith Water Products Company.



Propane Gas
A
B
C
6-Year
Model No.
Gal.
Cap.
Vent
Size
BTU Input
Per Hr.
Gal./Hr.*
Recovery
90F Rise
Height plus
Diverter
Height less
Diverter
Dia.
Approx. Ship.
Wt. (Lbs.)
Cost
FSG-30
30 3" 30,000 30.7
59
55 1/4
15 3/4
105
FSG-40 40 3" 30,000 30.7
57
53 1/4
18 1/4
119
FSG-50 50 3" 37,000 37.9
60 1/4
56 1/2
20 1/4
153
ENERGY SAVER MODELS

NOTE: To compensate for the effects of high altitude areas above 2,000 feet, recovery capacity should be reduced approximately 4 % for each 1,000 feet above sea level. ALL DIMENSIONS IN INCHES.

*Recovery capacities are based on DOE method of test.